Filter Results By:

Products

Applications

Manufacturers

Showing results: 16 - 29 of 29 items found.

  • CG01 - reference

    EMC Instruments Corporation

    The main application of Comb Generator is to quickly verify conducted emissions test setups. And the most important application is trouble shooting Open Area Test Sites(OATS).An OATS must be completely calibrated before it is put into service. reference signal source Noise Generators Signal Generators

  • CG01 - reference signal source

    EMC Instruments Corporation

    The main application of Comb Generator is to quickly verify conducted emissions test setups. And the most important application is trouble shooting Open Area Test Sites(OATS).An OATS must be completely calibrated before it is put into service. reference signal source Noise Generators Signal Generators

  • CG01- Signal Generators

    EMC Instruments Corporation

    The main application of Comb Generator is to quickly verify conducted emissions test setups. And the most important application is trouble shooting Open Area Test Sites(OATS).An OATS must be completely calibrated before it is put into service. reference signal source Noise Generators Signal Generators

  • CG01-signal source

    EMC Instruments Corporation

    The main application of Comb Generator is to quickly verify conducted emissions test setups. And the most important application is trouble shooting Open Area Test Sites(OATS).An OATS must be completely calibrated before it is put into service. reference signal source Noise Generators Signal Generators

  • Comb Generator

    CG01 - EMC Instruments Corporation

    The main application of Comb Generator is to quickly verify conducted emissions test setups. And the most important application is trouble shooting Open Area Test Sites(OATS).An OATS must be completely calibrated before it is put into service. reference signal source Noise Generators Signal Generators

  • 1GHz EMC Emissions Analyser

    SA1002 - Laplace Instruments Ltd.

    The SA1002 provides a high performance capability to measure the EMC compliance of your products. It covers the conducted emission and radiated emission bands to 1GHz, as required by most EMC standards. The included software is Windows compatible and simple to use. This powerful system automatically sets the analyser parameters to suit the test to be performed. Standard limits are available from simple pull-down menu. Results can be directly compared against these limits for easy checks on compliance status.

  • Line Impedance Stabilization Networks

    LISN - Com-Power Corporation

    LISN stands for 'Line Impedance Stabilization Network'. Com-Power offers a line of LISNs developed for conducted emission testing according to the most commonly adopted EMC specifications like CISPR, FCC, ISO, EN, RTCA DO-160 and MIL-STD 461D. The LISN circuit is designed and constructed to meet the performance criteria given by these standards.

  • EMC Accessories

    Rohde & Schwarz GmbH & Co. KG

    Complete your EMC test setup with the essential accessories to compliment the test equipment. Whether it is a LISN (or V-Network) to counteract interference from external power sources on conducted emissions from the device under test, probes to locate the near field sources of radiated emissions, receive and transmit antennas, or tripods for holding antennas in place, the Rohde & Schwarz catalog of EMC accessories provides the additional items you need for EMI and EMS measurements, guaranteed 100% suitable for use with Rohde & Schwarz EMC test equipment.

  • CARB Testing

    Underwriters Laboratories Inc.

    The ASTM D6007 (small chamber) and ASTM E1333 (large chamber) test methods are used by the composite wood products industry to measure emissions of formaldehyde from plywood, particle board and medium-density fiberboard (MDF), commonly known as CARB testing. Testing is conducted in environmental chambers operated at defined product loading, temperature and relative humidity.

  • General Purpose L-Chassis Single Output Power Supplies

    Series RTW - Kepco, Inc.

    Kepco's RTW series are general-purpose, L-chassis, single output power supplies.They are available in 50, 100, 150 and 300-watt power levels. Their small size and very low profile allow the RTW to be fitted into small spaces. They feature full safety compliance to international standards and have suppressed both conducted and radiated emission to FCC class B levels.

  • Transient Limiters

    Com-Power Corporation

    Transient limiter LIT-153A and LIT-930A protects a spectrum analyzer input from high-level transients from the line impedance stabilization networks during EMC conducted emissions testing. It has a combined frequency range of 9 kHz to 30 MHz. The built in high pass filter helps reduce 50/60 Hz line feed through. (see application notes)

  • 300W Generap Purpose U-Chassis Single-Output Power Supplies

    Series RMW - Kepco, Inc.

    Kepco's RMW series are 300-watt general-purpose, U-chassis, single output power supplies, with model RMW 51212K-300 offering a triple output: +5V and ±12V.Their small size and very low profile allow the RMW to be fitted into small spaces. They feature full safety compliance to international standards and have suppressed both conducted and radiated emission to FCC class B levels.

  • Emissions Test System

    PC-114 - Com-Power Corporation

    Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.

  • EMC Testing

    Keystone Compliance

    Keystone Compliance is a unique EMC test facility because of our focus on assisting our customers achieve the measurements and certifications that they are seeking. Our lab features three 3-meter EMC chambers and two military/aerospace EMC chambers. In addition to the chambers, the lab significant ground planes, equipment and software that optimize the efficiency of the testing. EMC TestingKeystone Compliance is a unique EMC test facility because of our focus on assisting our customers achieve the measurements and certifications that they are seeking. Our lab features three 3-meter EMC chambers and two military/aerospace EMC chambers. In addition to the chambers, the lab significant ground planes, equipment and software that optimize the efficiency of the testing.Our EMC/EMI testing capabilities include but are not limited to:Radiated immunity testing up to 200 V/m from 10 kHz to 40 GHzRadiated emissions testing up to 40 GHzSurge testing to 10kV/10kA – and higherElectrostatic Discharge “ESD” testing up to 30 kVConducted immunity testing to levels well above the highest defined “standard” levelsMagnetic field immunity testing up to 100 A/m continuous and 1000 A/m short/impulseCustomized transient waveforms to extend level, duration and/or repetition of the standard’s definitionShielding Effectiveness from small panels and boxes all the way up to large enclosures and cabling, with a wide dynamic range all the way to 40 GHzWhat differentiates Keystone Compliance from other EMI test labs is our consultative engineering and expedited EMI test reports. Our staff understand EMC/EMI testing and has extensive experience with radiated immunity, radiated emissions, conducted immunity, conducted emissions, surge, ESD and shielding effectiveness testing. We also cater to specialized testing requirements. If you do not see the test standard or testing requirement you are looking for, please contact us as we may still be able to assist you.For more information about our scope of accreditation, please visit the links below.CISPR StandardsIEC/EN Product Family StandardsIEC/EN Test StandardsISO, SAE and Vehicle StandardsMilitary StandardsFCC, North American and International StandardsShielding Effectiveness TestingLightning and Surge Testing

Get Help